Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
1.
Tomography ; 5(1): 99-109, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30854447

RESUMO

This multicenter study evaluated the effect of variations in arterial input function (AIF) determination on pharmacokinetic (PK) analysis of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) data using the shutter-speed model (SSM). Data acquired from eleven prostate cancer patients were shared among nine centers. Each center used a site-specific method to measure the individual AIF from each data set and submitted the results to the managing center. These AIFs, their reference tissue-adjusted variants, and a literature population-averaged AIF, were used by the managing center to perform SSM PK analysis to estimate Ktrans (volume transfer rate constant), ve (extravascular, extracellular volume fraction), kep (efflux rate constant), and τi (mean intracellular water lifetime). All other variables, including the definition of the tumor region of interest and precontrast T1 values, were kept the same to evaluate parameter variations caused by variations in only the AIF. Considerable PK parameter variations were observed with within-subject coefficient of variation (wCV) values of 0.58, 0.27, 0.42, and 0.24 for Ktrans, ve, kep, and τi, respectively, using the unadjusted AIFs. Use of the reference tissue-adjusted AIFs reduced variations in Ktrans and ve (wCV = 0.50 and 0.10, respectively), but had smaller effects on kep and τi (wCV = 0.39 and 0.22, respectively). kep is less sensitive to AIF variation than Ktrans, suggesting it may be a more robust imaging biomarker of prostate microvasculature. With low sensitivity to AIF uncertainty, the SSM-unique τi parameter may have advantages over the conventional PK parameters in a longitudinal study.


Assuntos
Neoplasias da Próstata/irrigação sanguínea , Neoplasias da Próstata/diagnóstico por imagem , Algoritmos , Artérias/diagnóstico por imagem , Meios de Contraste/farmacocinética , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Disseminação de Informação , Imageamento por Ressonância Magnética/métodos , Masculino , Modelos Biológicos , Neovascularização Patológica/diagnóstico por imagem , Reprodutibilidade dos Testes
2.
Tomography ; 2(1): 56-66, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27200418

RESUMO

Dynamic contrast-enhanced MRI (DCE-MRI) has been widely used in tumor detection and therapy response evaluation. Pharmacokinetic analysis of DCE-MRI time-course data allows estimation of quantitative imaging biomarkers such as Ktrans(rate constant for plasma/interstitium contrast reagent (CR) transfer) and ve (extravascular and extracellular volume fraction). However, the use of quantitative DCE-MRI in clinical prostate imaging islimited, with uncertainty in arterial input function (AIF, i.e., the time rate of change of the concentration of CR in the blood plasma) determination being one of the primary reasons. In this multicenter data analysis challenge to assess the effects of variations in AIF quantification on estimation of DCE-MRI parameters, prostate DCE-MRI data acquired at one center from 11 prostate cancer patients were shared among nine centers. Each center used its site-specific method to determine the individual AIF from each data set and submitted the results to the managing center. Along with a literature population averaged AIF, these AIFs and their reference-tissue-adjusted variants were used by the managing center to perform pharmacokinetic analysis of the DCE-MRI data sets using the Tofts model (TM). All other variables including tumor region of interest (ROI) definition and pre-contrast T1 were kept the same to evaluate parameter variations caused by AIF variations only. Considerable pharmacokinetic parameter variations were observed with the within-subject coefficient of variation (wCV) of Ktrans obtained with unadjusted AIFs as high as 0.74. AIF-caused variations were larger in Ktrans than ve and both were reduced when reference-tissue-adjusted AIFs were used. The parameter variations were largely systematic, resulting in nearly unchanged parametric map patterns. The CR intravasation rate constant, kep (= Ktrans/ve), was less sensitive to AIF variation than Ktrans (wCV for unadjusted AIFs: 0.45 for kepvs. 0.74 for Ktrans), suggesting that it might be a more robust imaging biomarker of prostate microvasculature than Ktrans.

3.
J Med Imaging (Bellingham) ; 3(1): 014503, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26989759

RESUMO

Matching the bolus arrival time (BAT) of the arterial input function (AIF) and tissue residue function (TRF) is necessary for accurate pharmacokinetic (PK) modeling of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI). We investigated the sensitivity of volume transfer constant ([Formula: see text]) and extravascular extracellular volume fraction ([Formula: see text]) to BAT and compared the results of four automatic BAT measurement methods in characterization of prostate and breast cancers. Variation in delay between AIF and TRF resulted in a monotonous change trend of [Formula: see text] and [Formula: see text] values. The results of automatic BAT estimators for clinical data were all comparable except for one BAT estimation method. Our results indicate that inaccuracies in BAT measurement can lead to variability among DCE-MRI PK model parameters, diminish the quality of model fit, and produce fewer valid voxels in a region of interest. Although the selection of the BAT method did not affect the direction of change in the treatment assessment cohort, we suggest that BAT measurement methods must be used consistently in the course of longitudinal studies to control measurement variability.

4.
Magn Reson Imaging ; 33(7): 886-94, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25683515

RESUMO

Accurate pharmacokinetic (PK) modeling of dynamic contrast enhanced MRI (DCE-MRI) in prostate cancer (PCa) requires knowledge of the concentration time course of the contrast agent in the feeding vasculature, the so-called arterial input function (AIF). The purpose of this study was to compare AIF choice in differentiating peripheral zone PCa from non-neoplastic prostatic tissue (NNPT), using PK analysis of high temporal resolution prostate DCE-MRI data and whole-mount pathology (WMP) validation. This prospective study was performed in 30 patients who underwent multiparametric endorectal prostate MRI at 3.0T and WMP validation. PCa foci were annotated on WMP slides and MR images using 3D Slicer. Foci ≥0.5cm(3) were contoured as tumor regions of interest (TROIs) on subtraction DCE (early-arterial - pre-contrast) images. PK analyses of TROI and NNPT data were performed using automatic AIF (aAIF) and model AIF (mAIF) methods. A paired t-test compared mean and 90th percentile (p90) PK parameters obtained with the two AIF approaches. Receiver operating characteristic (ROC) analysis determined diagnostic accuracy (DA) of PK parameters. Logistic regression determined correlation between PK parameters and histopathology. Mean TROI and NNPT PK parameters were higher using aAIF vs. mAIF (p<0.05). There was no significant difference in DA between AIF methods: highest for p90 volume transfer constant (K(trans)) (aAIF differences in the area under the ROC curve (Az) = 0.827; mAIF Az=0.93). Tumor cell density correlated with aAIF K(trans) (p=0.03). Our results indicate that DCE-MRI using both AIF methods is excellent in discriminating PCa from NNPT. If quantitative DCE-MRI is to be used as a biomarker in PCa, the same AIF method should be used consistently throughout the study.


Assuntos
Gadolínio DTPA/farmacocinética , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Modelos Biológicos , Neoplasias da Próstata/metabolismo , Neoplasias da Próstata/patologia , Idoso , Algoritmos , Simulação por Computador , Meios de Contraste/farmacocinética , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
5.
Transl Oncol ; 7(1): 153-66, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24772219

RESUMO

Pharmacokinetic analysis of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) time-course data allows estimation of quantitative parameters such as K (trans) (rate constant for plasma/interstitium contrast agent transfer), v e (extravascular extracellular volume fraction), and v p (plasma volume fraction). A plethora of factors in DCE-MRI data acquisition and analysis can affect accuracy and precision of these parameters and, consequently, the utility of quantitative DCE-MRI for assessing therapy response. In this multicenter data analysis challenge, DCE-MRI data acquired at one center from 10 patients with breast cancer before and after the first cycle of neoadjuvant chemotherapy were shared and processed with 12 software tools based on the Tofts model (TM), extended TM, and Shutter-Speed model. Inputs of tumor region of interest definition, pre-contrast T1, and arterial input function were controlled to focus on the variations in parameter value and response prediction capability caused by differences in models and associated algorithms. Considerable parameter variations were observed with the within-subject coefficient of variation (wCV) values for K (trans) and v p being as high as 0.59 and 0.82, respectively. Parameter agreement improved when only algorithms based on the same model were compared, e.g., the K (trans) intraclass correlation coefficient increased to as high as 0.84. Agreement in parameter percentage change was much better than that in absolute parameter value, e.g., the pairwise concordance correlation coefficient improved from 0.047 (for K (trans)) to 0.92 (for K (trans) percentage change) in comparing two TM algorithms. Nearly all algorithms provided good to excellent (univariate logistic regression c-statistic value ranging from 0.8 to 1.0) early prediction of therapy response using the metrics of mean tumor K (trans) and k ep (=K (trans)/v e, intravasation rate constant) after the first therapy cycle and the corresponding percentage changes. The results suggest that the interalgorithm parameter variations are largely systematic, which are not likely to significantly affect the utility of DCE-MRI for assessment of therapy response.

6.
Magn Reson Imaging ; 32(4): 321-9, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24560287

RESUMO

Multi-parametric Magnetic Resonance Imaging, and specifically Dynamic Contrast Enhanced (DCE) MRI, play increasingly important roles in detection and staging of prostate cancer (PCa). One of the actively investigated approaches to DCE MRI analysis involves pharmacokinetic (PK) modeling to extract quantitative parameters that may be related to microvascular properties of the tissue. It is well-known that the prescribed arterial blood plasma concentration (or Arterial Input Function, AIF) input can have significant effects on the parameters estimated by PK modeling. The purpose of our study was to investigate such effects in DCE MRI data acquired in a typical clinical PCa setting. First, we investigated how the choice of a semi-automated or fully automated image-based individualized AIF (iAIF) estimation method affects the PK parameter values; and second, we examined the use of method-specific averaged AIF (cohort-based, or cAIF) as a means to attenuate the differences between the two AIF estimation methods. Two methods for automated image-based estimation of individualized (patient-specific) AIFs, one of which was previously validated for brain and the other for breast MRI, were compared. cAIFs were constructed by averaging the iAIF curves over the individual patients for each of the two methods. Pharmacokinetic analysis using the Generalized kinetic model and each of the four AIF choices (iAIF and cAIF for each of the two image-based AIF estimation approaches) was applied to derive the volume transfer rate (K(trans)) and extravascular extracellular volume fraction (ve) in the areas of prostate tumor. Differences between the parameters obtained using iAIF and cAIF for a given method (intra-method comparison) as well as inter-method differences were quantified. The study utilized DCE MRI data collected in 17 patients with histologically confirmed PCa. Comparison at the level of the tumor region of interest (ROI) showed that the two automated methods resulted in significantly different (p<0.05) mean estimates of ve, but not of K(trans). Comparing cAIF, different estimates for both ve, and K(trans) were obtained. Intra-method comparison between the iAIF- and cAIF-driven analyses showed the lack of effect on ve, while K(trans) values were significantly different for one of the methods. Our results indicate that the choice of the algorithm used for automated image-based AIF determination can lead to significant differences in the values of the estimated PK parameters. K(trans) estimates are more sensitive to the choice between cAIF/iAIF as compared to ve, leading to potentially significant differences depending on the AIF method. These observations may have practical consequences in evaluating the PK analysis results obtained in a multi-site setting.


Assuntos
Gadolínio DTPA/farmacocinética , Interpretação de Imagem Assistida por Computador/métodos , Neovascularização Patológica/diagnóstico , Neovascularização Patológica/metabolismo , Neoplasias da Próstata/diagnóstico , Neoplasias da Próstata/metabolismo , Adulto , Idoso , Algoritmos , Estudos de Coortes , Simulação por Computador , Meios de Contraste/farmacocinética , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Modelos Biológicos , Projetos Piloto , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
7.
J Magn Reson Imaging ; 40(3): 730-7, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24307571

RESUMO

PURPOSE: To evaluate the usefulness of perfusion parameters derived from dynamic contrast-enhanced MR imaging (DCE-MRI) for assessing the therapeutic response to neoadjuvant chemoradiation therapy (CRT) for locally advanced rectal cancer (LARC). MATERIALS AND METHODS: Fifty patients with LARC (≥T3 or lymph-node metastasis) who underwent CRT and subsequent surgery, were included in this study. All patients underwent pre- and post-CRT DCE-MRI on a 1.5 Tesla unit. By using a postprocessing software, the following perfusion parameters (K(trans) , kep , ve ) were measured for tumor. Those perfusion parameters were compared not only between the T-downstaged group and the nondownstaged group, but also before and after CRT in each group. RESULTS: After CRT, the mean K(trans) (min(-1) ) significantly decreased from 1.24 ± 0.53 to 0.76 ± 0.45 in the T-downstaged group (n = 24) (P = 0.0007), whereas it did not significantly decrease in the nondownstaged group (n = 26) (from 1.02 ± 0.53 to 0.87 ± 0.48, P = 0.24). The percentage difference between pre- and post-CRT K(trans) in the T-downstaged group was significantly higher than that in the nondownstaged group (43%, 16%, respectively, P = 0.0092). However, none of the other parameters showed significant differences. CONCLUSION: A large decrease in the mean K(trans) after CRT was associated with a good therapeutic response to CRT for LARC.


Assuntos
Quimiorradioterapia , Imageamento por Ressonância Magnética/métodos , Terapia Neoadjuvante/métodos , Neoplasias Retais/patologia , Neoplasias Retais/terapia , Idoso , Terapia Combinada , Meios de Contraste , Feminino , Gadolínio DTPA , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Estadiamento de Neoplasias
8.
Europace ; 16(1): 133-41, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24014803

RESUMO

AIMS: Prior work has demonstrated that magnetic resonance imaging (MRI) strain can separate necrotic/stunned myocardium from healthy myocardium in the left ventricle (LV). We surmised that high-resolution MRI strain, using navigator-echo-triggered DENSE, could differentiate radiofrequency ablated tissue around the pulmonary vein (PV) from tissue that had not been damaged by radiofrequency energy, similarly to navigated 3D myocardial delayed enhancement (3D-MDE). METHODS AND RESULTS: A respiratory-navigated 2D-DENSE sequence was developed, providing strain encoding in two spatial directions with 1.2 × 1.0 × 4 mm(3) resolution. It was tested in the LV of infarcted sheep. In four swine, incomplete circumferential lesions were created around the right superior pulmonary vein (RSPV) using ablation catheters, recorded with electro-anatomic mapping, and imaged 1 h later using atrial-diastolic DENSE and 3D-MDE at the left atrium/RSPV junction. DENSE detected ablation gaps (regions with >12% strain) in similar positions to 3D-MDE (2D cross-correlation 0.89 ± 0.05). Low-strain (<8%) areas were, on average, 33% larger than equivalent MDE regions, so they include both injured and necrotic regions. Optimal DENSE orientation was perpendicular to the PV trunk, with high shear strain in adjacent viable tissue appearing as a sensitive marker of ablation lesions. CONCLUSIONS: Magnetic resonance imaging strain may be a non-contrast alternative to 3D-MDE in intra-procedural monitoring of atrial ablation lesions.


Assuntos
Ablação por Cateter/métodos , Técnicas de Imagem por Elasticidade/métodos , Átrios do Coração/cirurgia , Infarto do Miocárdio/cirurgia , Cirurgia Assistida por Computador/métodos , Animais , Átrios do Coração/patologia , Infarto do Miocárdio/patologia , Ovinos , Suínos
9.
J Am Heart Assoc ; 2(3): e000161, 2013 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-23709564

RESUMO

BACKGROUND: Spontaneous intracerebral hemorrhage (ICH) is associated with blood-brain barrier (BBB) injury, which is a poorly understood factor in ICH pathogenesis, potentially contributing to edema formation and perihematomal tissue injury. We aimed to assess and quantify BBB permeability following human spontaneous ICH using dynamic contrast-enhanced magnetic resonance imaging (DCE MRI). We also investigated whether hematoma size or location affected the amount of BBB leakage. METHODS AND RESULTS: Twenty-five prospectively enrolled patients from the Diagnostic Accuracy of MRI in Spontaneous intracerebral Hemorrhage (DASH) study were examined using DCE MRI at 1 week after symptom onset. Contrast agent dynamics in the brain tissue and general tracer kinetic modeling were used to estimate the forward leakage rate (K(trans)) in regions of interest (ROI) in and surrounding the hematoma and in contralateral mirror-image locations (control ROI). In all patients BBB permeability was significantly increased in the brain tissue immediately adjacent to the hematoma, that is, the hematoma rim, compared to the contralateral mirror ROI (P<0.0001). Large hematomas (>30 mL) had higher K(trans) values than small hematomas (P<0.005). K(trans) values of lobar hemorrhages were significantly higher than the K(trans) values of deep hemorrhages (P<0.005), independent of hematoma volume. Higher K(trans) values were associated with larger edema volumes. CONCLUSIONS: BBB leakage in the brain tissue immediately bordering the hematoma can be measured and quantified by DCE MRI in human ICH. BBB leakage at 1 week is greater in larger hematomas as well as in hematomas in lobar locations and is associated with larger edema volumes.


Assuntos
Barreira Hematoencefálica/lesões , Barreira Hematoencefálica/patologia , Hemorragia Cerebral/patologia , Hematoma/patologia , Imageamento por Ressonância Magnética , Doença Aguda , Hemorragia Cerebral/etiologia , Feminino , Hematoma/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
10.
Nanomedicine (Lond) ; 8(12): 1969-83, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23534832

RESUMO

AIM: To develop a clinically applicable MRI technique for tracking stem cells in matrix-associated stem-cell implants, using the US FDA-approved iron supplement ferumoxytol. MATERIALS & METHODS: Ferumoxytol-labeling of adipose-derived stem cells (ADSCs) was optimized in vitro. A total of 11 rats with osteochondral defects of both femurs were implanted with ferumoxytol- or ferumoxides-labeled or unlabeled ADSCs, and underwent MRI up to 4 weeks post matrix-associated stem-cell implant. The signal-to-noise ratio of different matrix-associated stem-cell implant was compared with t-tests and correlated with histopathology. RESULTS: An incubation concentration of 500 µg iron/ml ferumoxytol and 10 µg/ml protamine sulfate led to significant cellular iron uptake, T2 signal effects and unimpaired ADSC viability. In vivo, ferumoxytol- and ferumoxides-labeled ADSCs demonstrated significantly lower signal-to-noise ratio values compared with unlabeled controls (p < 0.01). Histopathology confirmed engraftment of labeled ADSCs, with slow dilution of the iron label over time. CONCLUSION: Ferumoxytol can be used for in vivo tracking of stem cells with MRI.


Assuntos
Rastreamento de Células/métodos , Meios de Contraste/análise , Óxido Ferroso-Férrico/análise , Imageamento por Ressonância Magnética/métodos , Transplante de Células-Tronco , Células-Tronco/citologia , Animais , Artrite/patologia , Artrite/cirurgia , Células Cultivadas , Feminino , Fêmur/patologia , Fêmur/cirurgia , Articulações/patologia , Articulações/cirurgia , Soluções de Nutrição Parenteral/análise , Ratos , Ratos Nus
11.
Magn Reson Imaging ; 30(9): 1224-33, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22898681

RESUMO

There are many challenges in developing robust imaging biomarkers that can be reliably applied in a clinical trial setting. In the case of dynamic contrast-enhanced (DCE) MRI, one such challenge is to obtain accurate precontrast T(1) maps for subsequent use in two-compartment pharmacokinetic models commonly used to fit the MR enhancement time courses. In the prostate, a convenient and common approach for this task has been to use the same 3D spoiled gradient-echo sequence used to collect the DCE data, but with variable flip angles (VFAs) to collect data suitable for T(1) mapping prior to contrast injection. However, inhomogeneous radiofrequency conditions within the prostate have been found to adversely affect the accuracy of this technique. Herein we demonstrate the sensitivity of DCE pharmacokinetic parameters to precontrast T(1) values and examine methods to improve the accuracy of T(1) mapping with flip angle-corrected VFA SPGR methods, comparing T(1) maps from such methods with "gold standard" reference T(1) maps generated with saturation recovery experiments performed with fast spin-echo (FSE) sequences.


Assuntos
Meios de Contraste/farmacocinética , Imageamento por Ressonância Magnética/métodos , Neoplasias da Próstata/radioterapia , Adulto , Biomarcadores/metabolismo , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Masculino , Imagens de Fantasmas , Próstata/patologia , Reprodutibilidade dos Testes
12.
Radiology ; 259(3): 875-84, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21325035

RESUMO

UNLABELLED: Quantitative imaging biomarkers could speed the development of new treatments for unmet medical needs and improve routine clinical care. However, it is not clear how the various regulatory and nonregulatory (eg, reimbursement) processes (often referred to as pathways) relate, nor is it clear which data need to be collected to support these different pathways most efficiently, given the time- and cost-intensive nature of doing so. The purpose of this article is to describe current thinking regarding these pathways emerging from diverse stakeholders interested and active in the definition, validation, and qualification of quantitative imaging biomarkers and to propose processes to facilitate the development and use of quantitative imaging biomarkers. A flexible framework is described that may be adapted for each imaging application, providing mechanisms that can be used to develop, assess, and evaluate relevant biomarkers. From this framework, processes can be mapped that would be applicable to both imaging product development and to quantitative imaging biomarker development aimed at increasing the effectiveness and availability of quantitative imaging. SUPPLEMENTAL MATERIAL: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.10100800/-/DC1.


Assuntos
Biomarcadores , Diagnóstico por Imagem , Difusão de Inovações , Avaliação da Tecnologia Biomédica/normas , Pesquisa Biomédica/organização & administração , Conflito de Interesses , Aprovação de Equipamentos , Europa (Continente) , Humanos , Valor Preditivo dos Testes , Estados Unidos , United States Food and Drug Administration
13.
J Am Coll Cardiol ; 55(24): 2762-8, 2010 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-20538171

RESUMO

OBJECTIVES: This study evaluates how characterization of tissue heterogeneity of myocardial infarction by cardiovascular magnetic resonance (CMR) is associated with cardiovascular events (CVE) in patients with ischemic cardiomyopathy (ICM). BACKGROUND: Prior studies demonstrated that the quantification of myocardial scar volume by CMR is superior to left ventricular end-diastolic volume, left ventricular end-systolic volume, and left ventricular ejection fraction (LVEF) in predicting future CVE in ICM patients. Evaluation of infarct heterogeneity by measuring infarct core and border zones through CMR might have a higher association with CVE. METHODS: Seventy patients (mean LVEF: 25 +/- 11%) considered for revascularization or medical management +/- implantable cardiac defibrillator were enrolled. A 1.5-T GE MRI (Signa, GE Healthcare, Milwaukee, Wisconsin) was used to acquire cine and delayed enhancement images. The patients' core and border zones of infarcted myocardium were analyzed and followed for CVE. RESULTS: Larger infarct border zone and its percentage of myocardium were found in the 29 patients (41%) who had CVE (median 13.3 g [interquartile range (IQR) 8.4 to 25.1 g] vs. 8.0 g [IQR 3.0 to 14.5 g], p = 0.02 and 7.8% [IQR 4.9% to 17.0%] vs. 4.1% [IQR 1.9% to 9.3%], p = 0.02, respectively). The core infarct zone and its percentage of myocardium, left ventricular end-diastolic volume, left ventricular end-systolic volume, and LVEF were not statistically significant. Sub-analysis of the medical management and revascularization patients with CVE demonstrated that the medically managed patients had a larger border zone, whereas there was no difference between border and core zones in the revascularization group (p < 0.05). CONCLUSIONS: Quantification of core and border zones and their percentages of myocardium through CMR is associated with future CVE and might assist in the management of patients with ICM.


Assuntos
Cateterismo Cardíaco , Cardiomiopatias/complicações , Imageamento por Ressonância Magnética/métodos , Infarto do Miocárdio/diagnóstico , Miocárdio/patologia , Cardiomiopatias/diagnóstico , Cardiomiopatias/fisiopatologia , Progressão da Doença , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/complicações , Infarto do Miocárdio/fisiopatologia , Prognóstico , Reprodutibilidade dos Testes , Volume Sistólico/fisiologia , Função Ventricular Esquerda/fisiologia
14.
J Am Coll Cardiol ; 52(19): 1574-80, 2008 Nov 04.
Artigo em Inglês | MEDLINE | ID: mdl-19007595

RESUMO

OBJECTIVES: The purpose of this study was to investigate a noninvasive method for quantifying diffuse myocardial fibrosis with cardiac magnetic resonance imaging (CMRI). BACKGROUND: Diffuse myocardial fibrosis is a fundamental process in pathologic remodeling in cardiomyopathy and is postulated to cause increased cardiac stiffness and poor clinical outcomes. Although regional fibrosis is easily imaged with cardiac magnetic resonance, there is currently no noninvasive method for quantifying diffuse myocardial fibrosis. METHODS: We performed CMRI on 45 subjects (25 patients with heart failure, 20 control patients), on a clinical 1.5-T CMRI scanner. A prototype T(1) mapping sequence was used to calculate the post-contrast myocardial T(1) time as an index of diffuse fibrosis; regional fibrosis was identified by delayed contrast enhancement. Regional and global systolic function was assessed by cine CMRI in standard short- and long-axis planes, with echocardiography used to evaluate diastology. An additional 9 subjects underwent CMRI and endomyocardial biopsy for histologic correlation. RESULTS: Post-contrast myocardial T(1) times correlated histologically with fibrosis (R = -0.7, p = 0.03) and were shorter in heart failure subjects than controls (383 +/- 17 ms vs. 564 +/- 23 ms, p < 0.0001). The T(1) time of heart failure myocardium was shorter than that in controls even when excluding areas of regional fibrosis (429 +/- 22 ms vs. 564 +/- 23 ms, p < 0.0001). The post-contrast myocardial T(1) time shortened as diastolic function worsened (562 +/- 24 ms in normal diastolic function vs. 423 +/- 33 ms in impaired diastolic function vs. 368 +/- 20 ms in restrictive function, p < 0.001). CONCLUSIONS: Contrast-enhanced CMRI T(1) mapping identifies changes in myocardial T(1) times in heart failure, which appear to reflect diffuse fibrosis.


Assuntos
Gadolínio DTPA , Insuficiência Cardíaca/diagnóstico , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Miocárdio/patologia , Adulto , Análise de Variância , Mapeamento Potencial de Superfície Corporal , Estudos de Casos e Controles , Feminino , Fibrose/diagnóstico , Insuficiência Cardíaca Diastólica/diagnóstico , Insuficiência Cardíaca Sistólica/diagnóstico , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Probabilidade , Estudos Prospectivos , Valores de Referência , Índice de Gravidade de Doença
15.
Radiology ; 244(3): 727-35, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17709827

RESUMO

PURPOSE: To retrospectively compare three dynamic contrast material-enhanced magnetic resonance (MR) imaging (dynamic MR imaging) analytic methods to determine the parameter or combination of parameters most strongly associated with changes in tumor microvasculature during treatment with bevacizumab alone and bevacizumab plus chemotherapy in patients with inflammatory or locally advanced breast cancer. MATERIALS AND METHODS: This study was conducted in accordance with the institutional review board of the National Cancer Institute and was compliant with the Privacy Act of 1974. Informed consent was obtained from all patients. Patients with inflammatory or locally advanced breast cancer were treated with one cycle of bevacizumab alone (cycle 1) followed by six cycles of combination bevacizumab and chemotherapy (cycles 2-7). Serial dynamic MR images were obtained, and the kinetic parameters measured by using three dynamic analytic MR methods (heuristic, Brix, and general kinetic models) and two region-of-interest strategies were compared by using two-sided statistical tests. A P value of .01 was required for significance. RESULTS: In 19 patients, with use of a whole-tumor region of interest, the authors observed a significant decrease in the median values of three parameters measured from baseline to cycle 1: forward transfer rate constant (Ktrans) (-34% relative change, P=.003), backflow compartmental rate constant extravascular and extracellular to plasma (Kep) (-15% relative change, P<.001), and integrated area under the gadolinium concentration curve (IAUGC) at 180 seconds (-23% relative change, P=.009). A trend toward differences in the heuristic slope of the washout curve between responders and nonresponders to therapy was observed after cycle 1 (bevacizumab alone, P=.02). The median relative change in slope of the wash-in curve from baseline to cycle 4 was significantly different between responders and nonresponders (P=.009). CONCLUSION: The dynamic contrast-enhanced MR parameters Ktrans, Kep, and IAUGC at 180 seconds appear to have the strongest association with early physiologic response to bevacizumab. Clinical trial registration no. NCT00016549


Assuntos
Anticorpos Monoclonais/uso terapêutico , Neoplasias da Mama/diagnóstico , Neoplasias da Mama/tratamento farmacológico , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Anticorpos Monoclonais Humanizados , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Área Sob a Curva , Bevacizumab , Meios de Contraste/farmacocinética , Feminino , Gadolínio DTPA/farmacocinética , Humanos , Inflamação , Pessoa de Meia-Idade , Neovascularização Patológica , Estudos Retrospectivos , Estatísticas não Paramétricas
16.
Neoplasia ; 9(7): 546-55, 2007 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-17710157

RESUMO

Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is widely used to evaluate tumor permeability, yet measurements have not been directly validated in brain tumors. Our purpose was to compare estimates of forward leakage K(trans) derived from DCE-MRI to the estimates K obtained using [(14)C]aminoisobutyric acid quantitative autoradiography ([(14)C]AIB QAR), an established method of evaluating blood-tumor barrier permeability. Both DCE-MRI and [(14)C]AIB QAR were performed in five rats 9 to 11 days following tumor implantation. K(trans) in the tumor was estimated from DCE-MRI using the threeparameter general kinetic model and a measured vascular input function. K(i) was estimated from QAR data using regions of interest (ROI) closely corresponding to those used to estimate K(trans). K(trans) and K(i) correlated with each other for two independent sets of central tumor ROI (R = 0.905, P = .035; R = 0.933, P = .021). In an additional six rats, K(trans) was estimated on two occasions to show reproducibility (intraclass coefficient = 0.9993; coefficient of variance = 6.07%). In vivo blood-tumor permeability parameters derived from DCE-MRI are reproducible and correlate with the gold standard for quantifying blood tumor barrier permeability, [(14)C]AIB QAR.


Assuntos
Neoplasias Encefálicas/irrigação sanguínea , Neoplasias Encefálicas/diagnóstico , Imageamento por Ressonância Magnética/métodos , Ácidos Aminoisobutíricos , Animais , Autorradiografia , Barreira Hematoencefálica , Permeabilidade Capilar , Masculino , Ratos , Ratos Endogâmicos F344
17.
Circulation ; 115(15): 2006-14, 2007 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-17389270

RESUMO

BACKGROUND: The extent of the peri-infarct zone by magnetic resonance imaging (MRI) has been related to all-cause mortality in patients with coronary artery disease. This relationship may result from arrhythmogenesis in the infarct border. However, the relationship between tissue heterogeneity in the infarct periphery and arrhythmic substrate has not been investigated. In the present study, we quantify myocardial infarct heterogeneity by contrast-enhanced MRI and relate it to an electrophysiological marker of arrhythmic substrate in patients with left ventricular (LV) systolic dysfunction undergoing prophylactic implantable cardioverter defibrillator placement. METHODS AND RESULTS: Before implantable cardioverter defibrillator implantation for primary prevention of sudden cardiac death, 47 patients underwent cine and contrast-enhanced MRI to measure LV function, volumes, mass, and infarct size. A method for quantifying the heterogeneous infarct periphery and the denser infarct core is described. MRI indices were related to inducibility of sustained monomorphic ventricular tachycardia during electrophysiological or device testing. For the noninducible versus inducible patients, LV ejection fraction (30+/-10% versus 29+/-7%, P=0.79), LV end-diastolic volume (220+/-70 versus 228+/-57 mL, P=0.68), and infarct size by standard contrast-enhanced MRI definitions (P=NS) were similar. Quantification of tissue heterogeneity at the infarct periphery was strongly associated with inducibility for monomorphic ventricular tachycardia (noninducible versus inducible: 13+/-9 versus 19+/-8 g, P=0.015) and was the single significant factor in a stepwise logistic regression. CONCLUSIONS: Tissue heterogeneity is present and quantifiable within human infarcts. More extensive tissue heterogeneity correlates with increased ventricular irritability by programmed electrical stimulation. These findings support the hypothesis that anatomic tissue heterogeneity increases susceptibility to ventricular arrhythmias in patients with prior myocardial infarction and LV dysfunction.


Assuntos
Arritmias Cardíacas/diagnóstico , Imageamento por Ressonância Magnética/métodos , Infarto do Miocárdio/diagnóstico , Disfunção Ventricular Esquerda/fisiopatologia , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/terapia , Desfibriladores Implantáveis , Suscetibilidade a Doenças/diagnóstico , Técnicas Eletrofisiológicas Cardíacas , Feminino , Humanos , Imagem Cinética por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/complicações , Infarto do Miocárdio/fisiopatologia , Valor Preditivo dos Testes , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/terapia , Disfunção Ventricular Esquerda/complicações
18.
J Am Coll Cardiol ; 49(9): 939-45, 2007 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-17336716

RESUMO

OBJECTIVES: Our goal was to investigate whether the association between established cardiovascular risk factors and arterial reactivity differs between the lower and upper extremities. BACKGROUND: Resistance artery reactivity in the arm is associated with cardiovascular risk factors, coronary disease, and events. However, the relationship of lower versus upper extremity vasoreactivity to increasing cardiovascular risk factors has not been determined. METHODS: We studied 82 subjects in 3 groups: 33 young healthy (YH) (21 to 41 years), 30 older healthy (OH) (>50 years), and 19 older type 2 diabetic subjects (OD). We directly measured systolic shear rate, flow, and radius in brachial and femoral arteries at rest and during post-occlusion hyperemia using magnetic resonance imaging. RESULTS: Brachial and femoral systolic shear rate, flow, and radius were similar among the groups at rest. Brachial hyperemic shear rate and hyperemic flow normalized as a function of baseline radius were not statistically different when YH were compared with OH and OH with OD. In contrast, femoral hyperemic shear rate and hyperemic flow normalized to baseline radius were lower in OH than YH (680 +/- 236 s(-1) vs. 843 +/- 157 s(-1), p = 0.001, and 0.84 +/- 0.25 mm(1.27)/s vs. 1.01 +/- 0.16 mm(1.27)/s, p = 0.001) and lower in OD than OH (549 +/- 183 s(-1), p = 0.02, and 0.74 +/- 0.19 mm(1.27)/s, p = 0.046). CONCLUSIONS: Persons with increasing cardiovascular risk factor burden had progressively reduced arterial reactivity in lower but not upper extremities. This may help to explain why atherosclerosis usually develops more severely in legs than in arms, and suggests that legs may be more sensitive than arms for assessing early global atherosclerotic risk.


Assuntos
Artérias/fisiopatologia , Doenças Cardiovasculares/diagnóstico , Doenças Cardiovasculares/fisiopatologia , Extremidade Inferior/fisiopatologia , Extremidade Superior/fisiopatologia , Adulto , Fatores Etários , Idoso , Artérias/fisiologia , Artéria Braquial/fisiologia , Artéria Braquial/fisiopatologia , Doenças Cardiovasculares/etiologia , Diabetes Mellitus Tipo 2/complicações , Feminino , Artéria Femoral/fisiologia , Artéria Femoral/fisiopatologia , Humanos , Hiperemia/fisiopatologia , Extremidade Inferior/fisiologia , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Valores de Referência , Fatores de Risco , Resistência ao Cisalhamento , Extremidade Superior/fisiologia
19.
Circulation ; 114(1): 32-9, 2006 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-16801462

RESUMO

BACKGROUND: Accurate risk stratification is crucial for effective treatment planning after myocardial infarction (MI). Previous studies suggest that the peri-infarct border zone may be an important arrhythmogenic substrate. In this pilot study, we tested the hypothesis that the extent of the peri-infarct zone quantified by contrast-enhanced cardiac magnetic resonance (CMR) is an independent predictor of post-MI mortality. METHODS AND RESULTS: We studied 144 patients with documented coronary artery disease and abnormal myocardial delayed enhancement (MDE) consistent with MI. A computer-assisted, semiautomatic algorithm quantified the total infarct size and divided it into the core and peri-infarct regions based on signal-intensity thresholds (>3 SDs and 2 to 3 SDs above remote normal myocardium, respectively). The peri-infarct zone was normalized as a percentage of the total infarct size (%MDE(periphery)). After a median follow-up of 2.4 years, 29 (20%) patients died. Patients with an above-median %MDE(periphery) were at higher risk for death compared with those with a below-median %MDE(periphery) (28% versus 13%, log-rank P<0.01). Multivariable analysis showed that left ventricular systolic volume index and %MDE(periphery) were the strongest predictors of all-cause mortality (adjusted hazard ratio [HR] for %MDE(periphery), 1.45 per 10% increase; P=0.002) and cardiovascular mortality (adjusted HR, 1.51 per 10% increase; P=0.009). Similarly, after adjusting for age and left ventricular ejection fraction, %MDE(periphery) maintained strong and independent associations with all-cause mortality (adjusted HR, 1.42; P=0.005) and cardiovascular mortality (adjusted HR, 1.49; P=0.01). CONCLUSIONS: In patients with a prior MI, the extent of the peri-infarct zone characterized by CMR provides incremental prognostic value beyond left ventricular systolic volume index or ejection fraction. Infarct characteristics by CMR may prove to be a unique and valuable noninvasive predictor of post-MI mortality.


Assuntos
Imageamento por Ressonância Magnética/métodos , Infarto do Miocárdio/mortalidade , Infarto do Miocárdio/patologia , Idoso , Meios de Contraste , Doença da Artéria Coronariana/complicações , Feminino , Gadolínio DTPA , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/complicações , Projetos Piloto , Valor Preditivo dos Testes , Prognóstico , Medição de Risco , Disfunção Ventricular Esquerda/etiologia
20.
J Cardiovasc Magn Reson ; 7(4): 615-21, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16136850

RESUMO

We investigated whether endothelial-dependent arterial constriction during reduced shear can be measured using phase contrast magnetic resonance imaging (PCMRI). A cross-section of the femoral artery was acquired during a 5-minute distal occlusion in 33 subjects. Systolic shear rate and radius were measured from the velocity profile via a best-fit parabola. Systolic shear rate decreased immediately after cuff inflation (404 +/- 78 to 233 +/- 75 sec(-1) p < .0001). Radius decreased at 2 min into inflation (3.52 +/- .41 to 3.43 +/- .42 mm, p < .0001). In conclusion, arterial constriction during reduced flow can be measured using PCMRI. This new method may add important information toward a comprehensive evaluation of endothelial function.


Assuntos
Endotélio Vascular/fisiologia , Artéria Femoral/fisiologia , Imageamento por Ressonância Magnética , Resistência ao Cisalhamento , Vasoconstrição , Adulto , Velocidade do Fluxo Sanguíneo , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Modelos Lineares , Imageamento por Ressonância Magnética/métodos , Masculino , Valores de Referência , Reprodutibilidade dos Testes , Projetos de Pesquisa , Fatores Sexuais , Sístole
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...